PRODUCTS > Explosion Detection & Suppression

Field proven UV/IR detection provides high speed optical flame detection while maintaining immunity to sources of UV and IR radiation to avoid unwanted system discharges.  To reduce weight and the number of components one of the detectors also contains a manual release switch and the system control logic functions.  Additional optical flame detectors can be added to cover larger and/or shaded areas of the hazard.

Power backup modules provide up to 15 minutes of power to assure automatic system operation in the event of a catastrophic loss of power to the system.

A unique remote manual activation switch is available with its own power back-up providing the capability to manually operate the system up to 1 hour after loss of primary power.

The agent is stored in a pressurized cylinder typically discharging through a discharge tube to either a nozzle with either a 360 degree or 180 degree discharge pattern.  This nozzle option allows flexible location of the cylinder while providing the best nozzle location for fast agent delivery.

Typical response times for these system from start of fire until agent starts discharging through the nozzle is 30 milliseconds or 3/100 of a second.  Total time from start of fire to extinguishment can be as short as 90 milliseconds (9/100 second) and is typically well under 200 milliseconds (1/5 second).

 

Explosion Suppression System (ESS).pdf  NEW!!  Updated 6/14  
Backup Power Module.pdf
Crew Cylinder.pdf
Detector Controller.pdf
Optical Detector.pdf
Second Shot Liquid Cooling.pdf

Get more information about this product
  • Amerex Corporation
  • \
  • 7595 Gadsden Highway
  • \
  • PO BOX 81
  • \
  • Trussville, AL 35173-0081